Compare specifications
Use the API 5L line pipe supplier hub for PSL1, PSL2, X65 and LSAW selection.

Compare outside diameter, STD, SCH40, SCH80 and SCH160 wall thickness and theoretical six-metre weights for seamless pipe from NPS 1/4 to NPS 24 (OD 13.7–610 mm). This standard seamless pipe size chart covers both API 5L line pipe and ASTM seamless tube dimensions; send a line list for a grade- and PSL-specific quotation.
Pipe catalogues often use NPS, DN or inches, but a purchase order must identify the outside diameter and wall thickness in millimetres. For example, NPS 4 is not 4 inches outside diameter: it is approximately 114.3 mm OD. The chart below keeps NPS, OD, wall and weight together so that the same size name is not mistaken for an actual dimension.
Use NPS and OD together, then specify wall thickness or schedule. A size label alone is insufficient for quotation.
For small-diameter seamless tube, quote OD × wall in mm, length and grade. Tube and pipe terminology can overlap, so the actual dimensions govern.
Convert a six-metre table value to kg/m, or use kg/m × length × pieces to calculate order weight and container loading.
Use the API 5L line pipe supplier hub for PSL1, PSL2, X65 and LSAW selection.
The seamless pipe price guide explains price per tonne, kg and metre using the same reference band.
Compiled from current mill quotation sheets dated 4 November 2026. The tables publish nominal dimensions and theoretical weight only; commercial prices, stock quantities and unverified certification claims are deliberately excluded.
Ordering boundary: this is a dimensional reference, not a stock list, certificate, PSL confirmation or offer. Final grade, product specification level, dimensions, tolerances, coating, inspection and mill-test documents apply only to the confirmed purchase order.
| NPS | OD (mm) | SCH40 wall (mm) | SCH40 kg / 6 m | SCH80 wall (mm) | SCH80 kg / 6 m | SCH160 wall (mm) | SCH160 kg / 6 m |
|---|---|---|---|---|---|---|---|
| 1/4 | 13.70 | 2.24 | 3.80 | 3.02 | 4.77 | - | - |
| 3/8 | 17.10 | 2.31 | 5.06 | 3.20 | 6.58 | - | - |
| 1/2 | 21.30 | 2.77 | 7.59 | 3.73 | 9.70 | 4.78 | 11.68 |
| 3/4 | 26.70 | 2.87 | 10.12 | 3.91 | 13.18 | 5.56 | 17.39 |
| 1 | 33.40 | 3.38 | 15.01 | 4.55 | 19.42 | 6.35 | 25.41 |
| 1-1/4 | 42.20 | 3.56 | 20.35 | 4.85 | 26.80 | 6.35 | 33.68 |
| 1-1/2 | 48.30 | 3.68 | 24.30 | 5.08 | 32.49 | 7.14 | 43.48 |
| 2 | 60.30 | 3.91 | 32.62 | 5.54 | 44.89 | 8.74 | 66.68 |
| 2-1/2 | 73.00 | 5.16 | 51.79 | 7.01 | 68.44 | 9.53 | 89.50 |
| 3 | 88.90 | 5.49 | 67.75 | 7.62 | 91.64 | 11.13 | 128.07 |
| 4 | 114.30 | 6.02 | 96.45 | 8.56 | 133.92 | 13.49 | 201.21 |
| 5 | 141.30 | 6.55 | 130.59 | 9.53 | 185.80 | 15.88 | 294.69 |
| 6 | 168.30 | 7.11 | 169.57 | 10.97 | 255.37 | 18.26 | 405.37 |
| 8 | 219.10 | 8.18 | 255.28 | 12.70 | 387.84 | 23.01 | 667.60 |
| 10 | 273.00 | 9.27 | 361.73 | 15.09 | 575.84 | 28.58 | 1033.58 |
| 12 | 323.80 | 10.31 | 478.22 | 17.48 | 792.25 | 33.32 | 1432.07 |
| NPS | OD (mm) | STD wall (mm) | STD kg / 6 m | SCH40 wall (mm) | SCH40 kg / 6 m | SCH80 wall (mm) | SCH80 kg / 6 m |
|---|---|---|---|---|---|---|---|
| 14 | 355.60 | 9.53 | 487.98 | 11.13 | 567.27 | 19.05 | 948.61 |
| 16 | 406.40 | 9.53 | 559.61 | 12.70 | 739.80 | 21.44 | 1221.19 |
| 18 | 457.00 | 9.53 | 630.96 | 14.27 | 934.78 | 23.83 | 1527.31 |
| 20 | 508.00 | 9.53 | 702.87 | 15.09 | 1100.53 | 26.19 | 1867.05 |
| 24 | 610.00 | 9.53 | 846.70 | 17.48 | 1532.46 | 30.96 | 2652.49 |
This existing frequently quoted size table is retained in full as a second reference. It includes selected fluid, boiler and line-pipe sizes across NPS 1–10 plus additional wall options.
| Outside diameter (mm) | NPS | Wall thickness (mm) | Weight (kg/m) | Weight per 6 m (kg) | Weight per 12 m (kg) |
|---|---|---|---|---|---|
| 33.4 | 1" | 3.38 | 2.5 | 15.01 | 30.03 |
| 48.3 | 1½" | 3.68 | 4.05 | 24.3 | 48.59 |
| 60.3 | 2" | 3.91 | 5.44 | 32.62 | 65.25 |
| 60.3 | 2" | 5.54 | 7.48 | 44.89 | 89.77 |
| 76 | 2½" | 4 | 7.1 | 42.61 | 85.22 |
| 76 | 2½" | 5.16 | 9.01 | 54.08 | 108.17 |
| 88.9 | 3" | 7.62 | 15.27 | 91.64 | 183.28 |
| 114.3 | 4" | 5 | 13.48 | 80.86 | 161.72 |
| 114.3 | 4" | 6.02 | 16.07 | 96.45 | 192.89 |
| 114.3 | 4" | 8.56 | 22.32 | 133.92 | 267.85 |
| 141.3 | 5" | 9.53 | 30.97 | 185.8 | 371.61 |
| 168.3 | 6" | 7.11 | 28.26 | 169.57 | 339.14 |
| 168.3 | 6" | 10.97 | 42.56 | 255.37 | 510.73 |
| 219.1 | 8" | 6.35 | 33.31 | 199.89 | 399.78 |
| 219.1 | 8" | 8.18 | 42.55 | 255.28 | 510.56 |
| 219.1 | 8" | 12.7 | 64.64 | 387.84 | 775.69 |
| 273.1 | 10" | 6.35 | 41.77 | 250.62 | 501.25 |
Six-metre weights are theoretical values calculated as (OD − wall) × wall × 0.02466 × 6. Actual shipment weights can differ because of diameter, wall and length tolerances. A dash means the schedule was not listed in the source sheet.
These outside diameters are the usual Chinese mill sizes for mechanical, hydraulic and high-pressure service, normally supplied in heavier walls.
| Size (OD × wall, mm) | Weight (kg/m) | Weight per 6 m (kg) | Weight per 12 m (kg) |
|---|---|---|---|
| 89 × 12 | 22.79 | 136.72 | 273.43 |
| 89 × 16 | 28.8 | 172.82 | 345.63 |
| 89 × 20 | 34.03 | 204.18 | 408.37 |
| 89 × 25 | 39.46 | 236.74 | 473.47 |
| 102 × 8 | 18.54 | 111.27 | 222.53 |
| 102 × 10 | 22.69 | 136.12 | 272.25 |
| 102 × 12 | 26.63 | 159.8 | 319.59 |
| 102 × 20 | 40.44 | 242.65 | 485.31 |
| 102 × 25 | 47.47 | 284.82 | 569.65 |
| 114 × 12 | 30.18 | 181.1 | 362.21 |
| 114 × 16 | 38.67 | 232 | 464 |
Theoretical weights. Actual shipment weight is confirmed on the mill certificate and the loading tally, and can differ by 1–3% because of wall and length tolerances.
Weight per metre (kg/m) = (outside diameter − wall thickness) × wall thickness × 0.02466
Example: 168.3 × 7.11 mm → (168.3 − 7.11) × 7.11 × 0.02466 = 28.26 kg/m. A 6 m length weighs about 169.6 kg; 100 lengths come to about 17.0 tonnes.
Weight per metre × length × number of pieces. Add 1–3% if you are sizing a truck or a container, because the mill weighs actual pipe, not theoretical pipe.
Send the line list and we return the weight calculation with the quotation — it costs you nothing and avoids an overweight container.
Container loading is planned at 28 metric tonnes per 40 ft container where dimensions and packing permit. Light walls run out of volume before they run out of weight; heavy walls run out of weight first. We issue a loading plan with bundles, pieces and total weight before the booking is made.
| Chinese grade and standard | Closest international equivalent | Typical service |
|---|---|---|
| 20# to GB/T 8163 | ASTM A106 Gr.B · EN 10216-2 P265GH | Fluid transmission, general piping |
| 20# to GB 3087 | ASTM A106 Gr.B · DIN 17175 St45.8 | Boiler and superheater tubes |
| 20# to GB 9948 | ASTM A106 Gr.B · ASTM A179 / A192 | Heat exchanger and condenser tubes |
| API 5L Gr.B / X42 | ISO 3183 L245 / L290 | Oil and gas line pipe |
| Alloy A335 P11 / P22 / P91 | EN 10216-2 10CrMo9-10 / 13CrMo4-5 / X10CrMoVNb9-1 | High temperature and pressure service |
Equivalent grades are given to help you compare specifications; the standard named on the purchase order and the mill certificate governs the delivery.
Weight in the chart is theoretical, calculated as (OD − wall) × wall × 0.02466 kg/m. These photographs show how the pipe is stocked and measured before it is weighed for a quotation.





Send the standard, outside diameter, wall thickness, grade, quantity and destination port. If you only have a tender document or a piping class, send that instead — we will read it and come back with the pipe specification.
| Sales e-mail | info@yuxindapipe.com |
|---|---|
| WhatsApp / Phone | +86 188 9221 5978 |
| Jiangyu Xue on LinkedIn — sales contact, replies in English | |
| Export base & port | Tianjin, China — 40 minutes from Tianjin Port |
| Working hours | Monday–Saturday, 08:30–20:00 (GMT+8) |
| Languages | English · Français · العربية · Português |
Your details are used only to answer this enquiry. No mailing list, no third parties.
Send it as it is. You will receive the material confirmation, the weight calculation and the price.